<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-23 13-04-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 50 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 21 kHz 6984 1,5893
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,0 dBr 3,84 dBr 5,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 21 kHz MIN: 16 kHz % above 76 kHz: 1,5893 Acquired: 2025/06/23 13.03.52 Total samples: 6984 Equivalent time: 0:05:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 5,8 dBr MIN: 2,0 dBr AVE: 3,84 dBr % above 12,2 dBr: 0,0 Last value: 4,6 dBr (2025/06/23 13.03.52) 12.50 12.52 12.54 12.56 12.58 13.00 13.02 0 2 4 6 Pm [dBr]